PLEASE NOTE: Effective 2019, we no longer supply Control Techniques variable frequency drives and components. We have drives from several other manufacturers which can meet or exceed the performance characteristics of the Control Techniques line. Simply complete the form below, or contact us with the model of your current or obsolete Control Techniques drive and we’ll be glad to identify a suitable replacement.

Also, the Fincor and Saftronics lines of AC variable frequency drives, DC variable speed drives, and reduced voltage starters were once owned by Emerson but have been obsolete for several years. However, we have many years’ experience working with these drives and can quickly identify replacements capable of exceeding the quality and performance of these older drive technologies. For a suitable replacement, fill out the form below or contact us with your drive or application requirements, and we’ll handle it from there!


Saftronics  

Obsolete Drive Replacement RFQ -

If you need a replacement for an existing obsolete drive, complete the following form and we will send you a quote for a suitable replacement.

* Required

Is an encoder or tachometer being used for speed feedback to the drive?:
Opt-In to our e-mail list:

(Obsolete) Saftronics GP10 – General Purpose Open Loop Vector AC Drive (Obsolete FINCOR Series 5700)

Options & Accessories

Description Part Number Price
Keypad Extension Cable – 2m Straight 018-G102 $ CALL
Keypad Extension Cable – 5m Coiled 018-G105 $ CALL
Keypad Extension Cable – 10m Coiled 018-G1010 $ CALL
Saflink Kit – Hardware & Software 046-GP10SL $ CALL
Saflink – Software only 046-3021 $ CALL
Palm Pilot Saflink Kit 046-7030 $ CALL
SR10 Highspeed Wireless Link for GP1 0 046-9028 $ CALL
Relay Output Card SOPCG11SRY $ CALL
Digital Interface Card SOPCG11SDI0 $ CALL
Analog Interface Card SOPCG11SAI0 $ CALL
Profibus DP Serial Communication SOPCG11SPDP $ CALL
DeviceNet Serial Communication SOPCG11SDEV $ CALL
Modbus Plus Serial Communication SOPCG11SMBP $ CALL
Interbus S Serial Communication SOPCG11SIBS $ CALL
LONWorks Communication SOPCG11SLON $ CALL
Custom 1/0 Card (Isolation Card) SOPCG11SCIO $ CALL
MetaSys N2 Communication SOPCG11SMN2 $ CALL
Genius Communication SHE300GEN150 $ CALL
Siemens Serial Communication SOPCG11SP1 $ CALL
SF10 Ethernet Module 046-7034 $ CALL
Control Net (External DIN Rail Mount) C/F $ CALL
120/24V I/P Board with 4 Relays (External Mount) 043-0303 $ CALL
120/24V IP Board 100-0171-01 $ CALL
Pressure Transducer Card with 4-20mA Outputs 100-0163-01 $ CALL
Sleep Function / Ref Loss Card 100-0175-01 $ CALL
HMI Pump Controller 043-0906 $ CALL
Keypad Mounting Kit Nema 1/12 with 2 Meter Cable 043-1010-2 $ CALL
Keypad Mounting Kit Nema 1/12 with 5 Meter Cable 043-1010-5 $ CALL
Keypad Mounting Kit Nema 1/12 with 10 Meter Cable 043-1010-10 $ CALL
Keypad Mounting Kit Nema 4/3R with 2 Meter Cable 043-1012-2 $ CALL
Keypad Mounting Kit Nema 4/3R with 5 Meter Cable 043-1012-5 $ CALL
Keypad Mounting Kit Nema 4/3R with 10 Meter Cable 043-1012-10 $ CALL
Heatsink Mounting Kit 1/4, 1/2, 1 Hp, Heatsink through Panel 043-0901 $ CALL
Heatsink Mounting Kit 2-5HP Heatsink through Panel 043-0902 $ CALL
Heatsink Mounting Kit 7-10HP HD, 7.5-15HP ND, Heatsink through Panel 043-0903 $ CALL
Heatsink Mounting Kit 15-25HP HD, 20-30HP ND, Heatsink through Panel 043-0904 $ CALL

Contact Joliet Technologies for price and availability of these units

Options & Accessories

The drive supports two internally mounted cards. One option card is mounted under the main cover (location A) and the other option card is mounted in a special adapter under the keypad (location B), refer to option card instruction manual for mounting information. There are two different types of option cards, Type 1 and Type 2. Two Type 1 or two type 2 cards cannot be used at the same time. Combinations of Type 1 and Type 2 may be used as long as there is only one per mounting location and follows the chart below. Each option card must be mounted in the designated location. The chart below lists the option card, their type and their mounting location.

Name Type Loc 2nd Option Type/Loc Function
SOPCG11SRY (Relay output card) 1 A 2/B – Relay output card The transistor output from the drive controls output terminals Y1 through Y4 which are converted to the relay outputs (1 SPOT, 3A, 250 VAC).
SOPCG11SDIO (Digital interface card) 2 A None – Frequency setting by binary code (max. 16 bits) – Monitoring (8 bits) of frequency, output current, and output voltage
SOPCG11SAI0 (Analog interface card) 2 A None – Auxiliary input for analog frequency setting (0 to +/-10 V) – Monitoring of drive output frequency, current, and torque in analog voltage
SOPCG11SCIO (Interface card) 2 A 2/B – 115 VAC Control input, an isolation amplifier,  relay output PG encoder
SOPCG11SLON (Communication Card) 2 B 1/A – Serial communication card for LonWorks
SOPCG11SPDP (Communication Card) 2 B 1/A – Serial communication card for Profibus-DP
SOPCG11SDEV (Communication Card) 2 B 1/A – Serial communication card for Device Net
SOPCG11SCOP (Communication Card) 2 B 1/A  Serial communication card for CAN
SOPCG115MBP (Communication Card) 2 B 1/A – Serial communication card for Modbus Plus
SOPCG11SIBS (Communication Card) 2 B 1/A – Serial communication card for Interbus-S
SHE300GEN150 (Communication Card) 2 B 1/A – Serial communication card for Genius
SOPG11SP1 (Communication Card) 2 B 1/A – Serial communication card for Siemens
100-0163-01 (Air Pressure Sensor VII Converter) 2 A None – Air Pressure Sensor and VII Converter This card provides a 4-20mA output signal with a 3-15PSI applied and converters FMA and FMP to 4-20mA outputs
100-0175-01 (Sleep Function) 2 A None – Monitors 3 Independent I/P functions and provides 3 Form C Relay outputs for control functions, such as sleep function, high/low torque level or Ref loss.
100-0171-01 (120V Card) 2 A None 24VDC + 24/120 VAC input control circuitry

To purchase any Saftronics drives or information, contact us at: Phone (815) 725-9696, Toll Free (866) 492-9888, Fax (815) 725-9393 or E-mail info@joliettech.com