ABB - ACS150 AC Variable Frequency Component DrivesABB General Machinery Drives
ACS350, 0.5hp to 10hp Technical Guide

Ratings, types, voltages and construction

ACS350

01U

02A4

2

+

J404

Type code
This is a unique reference number that clearly identifies the drive by power rating, voltage, and construction. Once you have selected the type code, the frame size can be used to determine the drive dimensions, shown on the next page.
Voltages
The ACS350 is available in two voltage ranges: 2 = 200 – 240 V
4 = 380 – 480 V
Construction
“01U” or the “03U” within the type code indicates the number of input phases for the power and EMC filtering. 01 = 1-phase (200 – 240V only)
03 = 3-phase (200 – 240V and 380 – 480V)
U = EMC filter disconnected, 60 Hz frequency
(In case the filter is required it can easily be connected.)

Notes for Product Selection

General Notes

  • I2N: continuous base current at 40°C (104°F) and 50°C (120°F). Overload cycle 150% for 1 minute / 10 minutes allowed.
  • Continuous output current at 5O°C (120°F) shown for 230Vac NEC motor ratings.
    When used at 50°C (120°F) at input voltages less than 230Vac may require larger drive.
  • Current ratings do not change with different supply voltages.
  • The rated current of the ACS350 must be greater than or equal to the rated motor current to achieve the rated motor power given in the table.
  • Horsepower ratings are based on NEC motor ratings for typical 4-pole motors (1800 rpm). Check motor nameplate current for compatibility.

240Vac Ratings (pricing)

3-phase supply voltage 208, 230 or 240 V. The power ratings are valid at nominal voltage, 208Vac at 40°C (104°F) or 230Vac at 50°C (120°F).

Type Code

Nominal ratings

IP 20

40°C (104°F)
Continuous Rating

50°C (120°F)
Continuous Rating

Frame
Size

I2N A PN HP I2N A PN HP

Price

1-Phase Un = 200…240V (200, 208, 230, 240V)
ACS350-01U-02A4-2+J404 2.4 0.5 2.2 0.50 R0 CALL
ACS350-01U-04A7-2+J404 4.7 1 4.2 1.0 R1 CALL
ACS350-01U-06A7-2+J404 6.7 1.5 6.0 1.5 R1 CALL
ACS350-01U-07A5-2+J404 7.5 2 6.8 2 R2 CALL
ACS350-01U-09A8-2+J404 9.8 3 8.8 2 R2 CALL
3-Phase Un = 200…240V (200, 208, 230, 240V)
ACS350-03U-02A4-2+J404 2.4 0.50 2.2 0.50 R0 CALL
ACS350-03U-03A5-2+J404 3.5 0.75 3.2 0.75 R0 CALL
ACS350-03U-04A7-2+J404 4.7 1 4.2 1 R1 CALL
ACS350-03U-06A7-2+J404 6.7 1.5 6.0 1.5 R1 CALL
ACS350-03U-07A5-2+J404 7.5 2 6.8 2 R1 CALL
ACS350-03U-09A8-2+J404 9.8 3 8.8 2 R2 CALL
ACS350-03U-17A6-2+J404 17.6 5 15.8 5 R2 CALL

For your specific application contact us for pricing.

480Vac Ratings (pricing)

3-phase supply voltage 380, 400, 415, 440 or 480 V. The power ratings are valid at nominal voltage, 480Vac at 50°C (120°F).

Type Code

Nominal ratings

IP 20

40°C (104°F)
Continuous Rating

50°C (120°F)
Continuous Rating

Frame
Size

I2N A PN HP I2N A PN HP

Price

3-Phase Un = 380…480V (380, 400, 415, 440, 460, 480V) 
ACS350-03U-01A2-4+J404 1.2 0.5 1.1 0.5 R0 CALL
ACS350-03U-01A9-4+J404 1.9 0.75 1.7 0.75 R0 CALL
ACS350-03U-02A4-4+J404 2.4 1 2.2 1 R0 CALL
ACS350-03U-03A3-4+J404 3.3 1.5 3.0 1.5 R1 CALL
ACS350-03U-04A1-4+J404 4.1 2 3.7 2 R1 CALL
ACS350-03U-05A6-4+J404 5.6 3 5.0 3 R1 CALL
ACS350-03U-08A8-4+J404 8.8 5 7.9 5 R1 CALL
ACS350-03U-12A5-4+J404 12.5 7.5 11.3 7.5 R3 CALL
ACS350-03U-15A6-4+J404 15.6 10 14.0 10 R3 CALL

For your specific application contact us for pricing.

ABB Inc.

ABB Inc.
Low Voltage Drives
16250 W. Glendale Drive
New Berlin, WI 53151
ABB Inc.
Drives & LVC Canada
3299 J.B. Deschamps Blvd.
Lachine, Quebec H8T 3E4
Telephone
Fax
Internet
 (800) 752-0696
(262) 785-0397
http://www.abb.us/drives
Telephone
Fax
Internet
 (800) 215-3006
(514) 420-3137
http://www.abb.com/motors&drives
http://www.abb-drives.com

© 2006 ABB Inc. ACS350-PHTC01U-EN REV B, Effective: 1/1/06.
Specifications subject to change without notice.