MOTORTRONICS
|
Integrated bypass contactor
|
VMX Series Specifications
Power Components
- 6 SCRs in inverse parallel pairs for full phase angle soft start control
- 1600V PIV rating on all units
- RC snubber for dv/dt protection of each SCR pair
Line Voltage Range
- 200 to 600 VAC, 3 phase + 10% -15% on all units, 50/60Hz
Current Ratings
- 18 – 1250A depending on unit selection
- Range of each unit is 50-100% of maximum current rating based on 1.0 service factor
AC Supply Voltage
- User supplied 120VAC + 10% -15% tolerance, 60Hz
- Optional 240VAC 50Hz control available
Overload Capacity (% of motor FLA)
- 600% for 10 seconds, 350% for 30 seconds
- 100% of Max Amp rating continuous per UL
Bypass Contactor
- Standard on all units
- Non-bypassed model available 21 OA & above (refer to product selection guide)
- Heavy Duty (Across-the-Line) rated models available (refer to VMX-HD Series in product selection guide)
Start/Stop Control Choices
- 2-wire Run-Stop using dry contacts
- 3-wire Start/Stop with built-in seal in contact
- N.C. lnterlock input (dry contact) for remote devices
Ramp Control Choices (4 built-in)
- Voltage Ramp
- Voltage Ramp with Current Limit
- CLT© Closed Loop Torque Ramp (Current Ramp)
- Current Step (current limit only)
- Ramp times adjustable 1 – 120 seconds
- Current Limit adjustable 200 – 600% of FLA
Dual Ramps
- Select via dry contact closure between any combinations of the above
Certifications
Jog
- Dry contact closure selects a non-ramping Jog function at an adjustable torque
Kick Start
- 10 – 100% starting torque for 0.1 – 2 seconds
Pump-Flex™ Deceleration Ramp
- Fully adjustable to match field conditions:
- Begin Decel setting, 0 – 100% of line voltage
- Decel ramp time, 1 – 60 seconds
- End Decel setting (Of£), 0 – 1 % of Begin setting
Restart Delay Timer (Sequential Start Delay)
- Programmable time delay 1 – 999 seconds after loss of control power for staggered restarts
Time Clock Controller
- 24 hour/7 day time clock to provide automatic start
- Up to 7 start events per day
- Select operation from 1 through 7 days per week
- Run time determined by process control timer
Process Control Timer (choice of either)
- Minimum Run (Batch) Timer
- 1- 999 minutes
- Runs until time expires, resets only if expired
- Resumes and finishes if stopped or power is lost
- Permissive Run Timer
- 1- 999 minutes
- Only allows operation during active run time
RS-485 Serial Communications
- up to 247 starters per link
- Modbus RTU protocol built-in
- Full programming over the serial link
- Programmable remote starter control
Operator Interface
- Tactile feedback keypad
- Easy to read LED display
- Run and fault status indicators