ABB ACS800 AC DRIVES

0.5 to 100Hp @ 208 to 240V
1.5 to 600Hp @ 380 to 500V

ACS 800 Specifications

Input Connection
Input Voltage (U1) 208/220/230/240 VAC 3-phase +/-10% for 200 VAC units 380/400/415/440/460/480/500 VAC 3-phase +/-10% for 480 VAC units
Input Frequency 48 to 63 Hz, maximum rate of change 17%/second
Line Imbalance Max +/-3% of nominal phase to phase input voltage
Fundamental Power Factor (cos�) Connection 0.98 (at nominal load)
Output Connection
Output Voltage 0 to U1 3-phase symmetrical, UN at the field weakening point
Output Frequency -300 to +300 Hz, in DTC mode (0-3.2((U1 input voltage/UN motor)*fN motor))
Frequency Resolution 0.01 Hz
Continuous Current 1.0 * I2N (normal use)
1.0 * I2hd (heavy-duty use)
Short Term Overload Capacity INmax = 1.1 * I2N (1 min /5 minutes @ 40°C), typical
INhdmax = 1.5 * I2hd (at least 1 min / 5 min @ 40°C)
Peak Overload Capacity 1max (400 VAC and 500 VAC) (at least 10 seconds at start)
Field Weakening Point 8 to 300 Hz
Switching Frequency 3 kHz (average)
Acceleration Time 0 to 1800 s
Deceleration Time 0 to 1800 s
Efficiency 98% at nominal power level
Short Circuit Withstand Rating 65,000 AIC (UL) R2-R8
Connection U2, V2, W2
Ambient Conditions, Operation
Air Temperature 0° to 40°C (104°F), above 40°C the maximum output current is de-rated 1% for every additional 1°C (up to 50°C (122°F) maximum limit)
Relative Humidity 5 to 95%, no condensation allowed, maximum relative humidity is 60% in the presence of corrosive gasses
Contamination Levels
IEC 60721-3-1,60721-3-2 and 60721-3-3
Chemical Gasses 3C1 (w/o coating), 3C2 (with coating)
Solid Particles 3S2
Installation Site Altitude 0 to 1000 m (3300 ft) above sea level. At sites over 1000 m above sea level, the maximum power is de-rated 1 % for every additional 1 00 m (330 ft). If the installation site is higher than 2000 m above sea level, please contact your local ABB distributor or representative for further information.
Vibration Max 1 mm (0.04″) 5 to 13.2 Hz, Max 7 m/s2 (23 ft/s2) 13.2 to 100 Hz sinusoidal
Ambient Conditions, Storage
Air Temperature -20° to 70°C (-4 ° to 158°F)
Relative Humidity Less than 95%, no condensation allowed
Atmospheric Pressure 70 to 106 kPa (10.2 to 15.4 PSI)
Vibration Max 1 mm (0.04″) 5 to 13.2 Hz, Max 7 m/s2 (23 ft/s2) 13.2 to 100 Hz
Shock (IEC 60068-2-29) Max 100 m/s2 (330 ft/s2) 11 ms
Ambient Conditions, Transportation
Air Temperature -20 to 70 C (-4 to 158 F)
Relative Humidity Max 95%
Atmospheric Pressure 60 to 106 kPa (8.7 to 15.4 PSI)
Vibration Max 3.5 mm (0.14″) 2 to 9 Hz, Max 15 m/s2 (49 ft/s2) 9 to 200 Hz sinusoidal
Shock (IEC 60068-2-29) Max 100 m/s2 (330 ft/s2) 11 ms
Free Fall 250 mm (weight under 100 kg)
100 mm (weight over 100 kg)
Cooling Information
Cooling Method Internal Fan
Power Loss Approximately 3% of rated power
Auxiliary Power Supply
Voltage 24 VDC, +/- 10%
Maximum Current 250 mA
Protection Short Circuit Protection
Terminal Block Size 0.3 to 3 mm2 (12 to 22 AWG)
Analog Inputs
Two Programmable Differential Current Inputs
Signal Level 0 (4) to 20mA
Input Resistance R1 = 100 ohms
One Programmable Differential Voltage Input
Signal Level -10 VDC 0 (2) VDC to +10 VDC
Input Resistance R1 = 200 k-ohms
Common Mode Voltage +/-15 VDC, max.
Common Mode Rejection Ratio > 60 dB at 50 Hz
Resolution 0.025% (12 bit)
Accuracy +/- 0.5%
Input Updating Time 6 ms (Standard Application Software)
Terminal Block Size Cables 0.3 to 3.3 mm2 (12 to 22 AWG)
Optional Isolation Available through  external Module
Reference Power Supply
Voltage +10 VDC, 0, -10 VDC +/- 0.5% at 25 C (77 F)
Maximum Load 10mA
Applicable Potentiometer 1 k-ohm to 10 k-ohm
Terminal Block Size Cables 0.3 to 3.3 mm2 (12 to 22 AWG)
Analog Outputs
Two Programmable Current Outputs
Signal Level 0 (4) to 20 mA
Resolution 0.025% (12 bit)
Accuracy +/-1% Full Scale Range) at 25 C (77 F), temperature coefficient +/- 200 ppm/C (+/- 111 ppm/F) max.
Maximum Load Impedance 700 ohms
Output Updating Time 24 ms, max
Terminal Block Sizes Cables 0.3 to 3.3 mm2 (12 to 22 AWG)
Digital Inputs
Six Programmable Digital Inputs (Common Ground), plus One Start Interlock
Isolation Isolated, can be divided in two isolated groups
Isolation Test Voltage 500 VAC, 1 minute
Terminal Block Size Cables 0.3 to 3.3 mm2 (12 to 22 AWG)
Signal Level 24 VDC, -15% to +20%
Logical Thresholds < 8 VDC at “0”, >12 VDC at “1”
Input Current 10 mA, Digital Input 1 to Digital Input 5, 5 mA Digital Input 6
Filtering Time Constant 1 ms
Input Updating Time 6 ms
Internal 24 VDC Supply for Digital Inputs
Voltage 24 VDC
Maximum Current 100 mA
Connector X22:7
Protection Short Circuit Proof
An external 24 VDC supply may be used instead of the internal supply
Relay Outputs
Three Programmable Relay Outputs
Switching Capacity 8 A at 24 VDC or 250 VAC, 0.4 A at 120 VDC
Maximum Continuous Current Ic = 2 A RMS
Contact Material Silver Cadmium Oxide (AgCdO)
Isolation Test Voltage 4 kVAC, 1 minute
Terminal Block Size Cables 0.3 to 3.3 mm2 (12 to 22 AWG)
Output Updating Time 100 ms
Protections
Single Phase Protected (input & output)
Overvoltage Trip Limit 1.3 * V1max
Undervoltage Trip Limit 0.65 * V1min
Overtemperature 140°C (284°F)
Auxiliary Voltage Short Circuit Protected
Ground Fault Protected
Microprocessor Fault Protected
Motor Stall Protection Protected
Motor Overtemperature Protection (I2t) Protected

U1 = lnput Voltage
UN = Nominal Motor Voltage
fN = Nominal Motor Frequency
I2N = Nominal Current – Normal Duty
IMax = Maximum Current for Peak Overload
SN = Power – Normal Duty (kVA)
PN = Power – Normal Duty (kW)
PN = Power – Normal Duty (HP)
I2hd = Nominal Current – Heavy-Duty
SNhd = Power (kVA) – Heavy-Duty
PNhd = Power (kW) – Heavy-Duty
PNhd = Power (HP) – Heavy-Duty

Contact Joliet Technologies for Custom Drive Pricing.
Phone: (815) 725-9696 or
Toll Free: (866) 492-9888
Fax: (815) 725-9393
E-mail: info@joliettech.com
RFQ – Request for Quote

© 2004 ABB Inc. All rights reserved Specification and pricing subject to change without notice.

ACS800-US-03
Rev. B

Effective: 06/11/03
Supersedes: 10/07/02