ABB ACS550 AC DRIVES
0.75 HP (.55 kW) to 100 HP (75 kW) @ 208 to 240V
1.0 HP (.75 kW) to 550 HP (355 kW) @ 380 to 480V
- Overview
- Hardware Description
- ACS550 Standard Features / Available Options
- ACS550 Specifications
- 230V Ratings (prices)
- 380V Ratings (prices)
- 480V Ratings (prices)
- Dimensions: ACS550 NEMA 1 R1 through R6 Frame Size
- Dimensions: ACS550 NEMA 12 R1 through R6 Frame Size
- Dimensions: ACS550-02 NEMA 1 R7 Frame Size
- Dimensions: ACS550-02 NEMA 1 R8 Frame Size
- Dimensions: ACS550-U2 NEMA 1 R7 & R8 Frame Size
ABB ACS550 AC DRIVES
ACS550 Features
Standard Features
- UL and cUL
- 1st Environment, Restricted Distribution CE Approval (30 m motor cable) for R1 – R6 frames – 2nd Environment for R7 & R8 Frames
- Start-Up Assistant
- Full Graphic and Multilingual Display
- Fused Disconnect (ACS550-U2 ONLY)
- Two (2) Programmable Analog Inputs
- Six (6) Programmable Digital inputs
- Two (2) Analog Outputs
- Adjustable Filters on Analog Inputs and Outputs
- Input Speed Signals
- Current 0 (4) … 20 mA
- Voltage 0… 10VDC
- Increase/Decrease Reference Contacts
- Fieldbus Adapters
- Start/Stop
- 2 Wire (Dry Contact Closure)
- 3 Wire (Momentary Dry Contacts)
- Adjustable Current Limit
- Adjustable Torque Limit
- Nine (9) Supervision Functions
- Electronic Reverse
- Motor ID Run
- Power Loss Ride-Through
- DC Injection Braking (in V/Hz ONLY)
- DC Magnetizing Start
- DC Hold
- Flux Braking
- Seven (7) Preset Speeds
- Three (3) Critical Speed Lockout Bands
- V/Hz, Sensorless and Flux Vector Modes of Motor Control (Flux vector not available at time of printing)
- Automatic Reset Customer Selectable
- Two (2) Independently Adjustable Accel and Decel Ramps
- Linear or Two (2) Adjustable US” Curve Accel/Decel Ramps
- Ramp or Coast to a Stop
- Maximum Frequency Programmable up to 500 Hz
- Two (2) Integral Independent Programmable PID Setpoint Controller
- Mathematical Functions on Analog Reference Signals
- Patent Pending Swinging Choke Design for Harmonic Mitigation (R1 – R4 frames) 5% impedance
- AC Input Line Reactor for Harmonic Mitigation (R5 – R8 frames) 3% impedance
- Integral Brake Chopper (R1 & R2 Frames)
- Emergency Stop Ramp
- Modbus RTU
- Programmable Fault Functions for Protection include:
- AI<Min
- Panel Loss
- External Fault
- Motor Thermal Protection
- Stall
- Underload
- Motor Phase Loss
- Ground Fault
- Preprogrammed Protections include:
- Overcurrent
- Short Circuit
- Overvoltage
- Undervoltage
- Input Phase Loss
- Output Device (IGBT) Overtemperature
- Motor Overtemperature Protection Wt)
Available Options
- 3 Relay Extension Module OREL-01
- 115/230 V Digital Input Interface Module OHDI-01
- Pulse Encoder Interface Module OTAC-01
- Fieldbus Adapter Modules
- DeviceNet RDNA-01
- Profibus-DP RPBA-01
- Braking Units and Choppers
- DriveWindow Light@-based Start-up, Operation, Programming and Diagnostic Tool
- Fan Replacement Kits
- Remote Panel Mounting Kit
- Flange Mounting Kits