380V Ratings
3-phase supply voltage 380, 400, 415, 440, 460, 480 or 500 V – Power ratings are valid at nominal voltage, 400 V (50Hz power line)
Type Code NEMA 1 (6,7) |
I max A (3) |
Nominal Ratings (4, 5) |
Frame Size |
Price | |||
Normal Duty (VT) (1) (110% I2N) |
Heavy-duty (CT) (2) (150% I2hd) |
||||||
I 2N A |
P N kW (8) |
I 2hd A |
P hd kW (8) |
||||
Wall Mounted Drives | |||||||
ACS800-U1-0004-5 | 6.5 | 4.5 | 1.5 | 3.4 | 1.1 | R2 | CALL |
ACS800-U1-0005-5 | 8.2 | 5.6 | 2.2 | 4.2 | 1.5 | R2 | CALL |
ACS800-U1-0006-5 | 10.8 | 7.7 | 3 | 5.6 | 2.2 | R2 | CALL |
ACS800-U1-0009-5 | 13.8 | 10 | 4 | 7.5 | 3 | R2 | CALL |
ACS800-U1-0011-5 | 17.6 | 12 | 5.5 | 9.2 | 4 | R2 | CALL |
ACS800-U1-0016-5 | 24 | 18 | 8 | 13 | 6 | R3 | CALL |
ACS800-U1-0020-5 | 32 | 23 | 11 | 18 | 8 | R3 | CALL |
ACS800-U1-0025-5 | 46 | 31 | 15 | 23 | 11 | R3 | CALL |
ACS800-U1-0030-5 | 62 | 39 | 18.5 | 32 | 15 | R4 | CALL |
ACS800-U1-0040-5 | 72 | 44 | 22 | 36 | 18.5 | R4 | CALL |
ACS800-U1-0050-5 | 86 | 61 | 30 | 50 | 22 | R5 | CALL |
ACS800-U1-0060-5 | 112 | 75 | 37 | 60 | 30 | R5 | CALL |
ACS800-U1-0070-5 | 138 | 88 | 45 | 69 | 37 | R5 | CALL |
ACS800-U1-0100-5 | 164 | 115 | 55 | 88 | 45 | R6 | CALL |
ACS800-U1-0120-5 | 202 | 145 | 75 | 113 | 55 | R6 | CALL |
ACS800-U1-0140-5 | 282 | 163 | 90 | 141 | 75 | R6 | CALL |
Free Standing Drives w/Extension Enclosure | |||||||
ACS800-U2-0170-5 | 326 | 192 | 90 | 162 | 90 | R7 | CALL |
ACS800-U2-0210-5 | 404 | 240 | 132 | 192 | 90 | R7 | CALL |
ACS800-U2-0260-5 | 432 | 284 | 160 | 224 | 110 | R7 | CALL |
ACS800-U2-0320-5 | 568 | 361 | 200 | 284 | 160 | R8 | CALL |
ACS800-U2-0400-5 | 720 | 477 | 250 | 361 | 200 | R8 | CALL |
ACS800-U2-0440-5 | 904 | 515 | 250 | 477 | 250 | R8 | CALL |
ACS800-U2-0490-5 | 1017 | 590 | 315 | 515 (10) | 250 | R8 | CALL |
ACS800-U2-0550-5 | 1017 | 632 | 355 | 590 (10) | 315 | R8 | CALL |
ACS800-U2-0610-5 | 1017 | 704 | 400 | 590 (10) | 315 | R8 | CALL |
For your specific application contact us for pricing. |
|||||||
Cabinet Drives | |||||||
ACS800-U2-0170-5+C111 +P901 +H358 | 326 | 192 | 90 | 162 | 90 | R7 | CALL |
ACS800-U2-0210-5+C111 +P901 +H358 | 404 | 240 | 132 | 192 | 90 | R7 | CALL |
ACS800-U2-0260-5+C111 +P901 +H358 | 432 | 284 | 160 | 224 | 110 | R7 | CALL |
ACS800-U2-0320-5+C111 +P901 +E208+H358 | 568 | 361 | 200 | 284 | 160 | R8 | CALL |
ACS800-U2-0400-5+C111 +P901 +E208+H358 | 720 | 477 | 250 | 361 | 200 | R8 | CALL |
ACS800-U2-0440-5+C111 +P901 +E208+H358 | 904 | 515 | 250 | 477 | 250 | R8 | CALL |
ACS800-U2-0490-5+C111 +P901 +E208+H358 | 1017 | 590 | 315 | 515 (10) | 250 | R8 | CALL |
ACS800-U2-0550-5+C111 +P901 +E208+H358 | 1017 | 632 | 355 | 590 (10) | 315 | R8 | CALL |
ACS800-U2-0610-5+C111 +P901 +E208+H358 | 1017 | 704 | 400 | 590 (10) | 315 | R8 | CALL |
Note: All drives are supplied w/Operator Control Panel. |
For your specific application contact us for pricing. |
NOTES
- I2N: continuous base current at 40°C (104°F). Overload cycle 110% I2N for 1 minute / 5 minutes allowed at 40°C (104°F).
- I2hd: continuous base current at 40°C (104°F). Overload cycle 150% I2hd for 1 minute / 100% 5 minutes allowed at 40°C (104°F).
- 1max: current available for 10 seconds at start.
- Current ratings do not change with different supply voltages.
- The rated current of the ACS 800 must be greater than or equal to the rated motor current to achieve the rated motor power given in the table.
- All -U1 models -0004 through -0140 come with a conduit box as standard.
- All-02 models -0170 through -0610 with added option codes come with bottom entry I exit, US conduit plate (H358) and common mode filters (E208) for drives -0320 and larger. The extended enclosure (C111) adds a fusible disconnect with power cabie entry and exit remaining bottom / bottom. If European conduit plate is desired, delete option H358 with no price change.
- Kilowatt rating is based upon IEC ratings for most 2,4 and 6-pole motors (3000, 1500, 1000 rpm). Check motor nameplate current for compatibility.
- When ordering 380V IP54 R6 units, order as ACS800-01-xxxx-5+B056+H358 (NOTE: This unit will NOT ship w/ a UL label).
- 140% I2hd overload current for 1 minute / 5 minutes if the ambient temperature is 40°C. 150% I2hd overload current for 1 minute / 5 minutes @ 30°C.