ABB ACS800 AC DRIVES
0.5 to 100Hp @ 208 to 240V
1.5 to 600Hp @ 380 to 500V
- Overview
- Standard Features / Available Options and Software
- Specifications
- Basic Type Code Information
- 230V Ratings (prices)
- 380V Ratings (prices)
- 460V Ratings (prices)
- ACS 800-U2 NEMA 1 R7 & R8 Frame Size and
ACS 800-02+C111 IP21 (NEMA 1) R7 & R8 Frame Size - ACS 800 NEMA 1/12 R2 through R6 Frame Size
- ACS 800-02 NEMA 1 R7 & R8 Frame Size
- ACS 800-U4 Module R7 Frame Size
- ACS 800-U4 Module R8 Frame Size
ACS 800 Features
Standard Features
- UL and CUL
- 80 Character Multilingual Alphanumeric Display
- Intelligent Start-Up Assistant
- Adaptive Programming Block with twenty (20) PLC-like functions
- Input Fusing and Fused Disconnect (ACS800-U2 only)
- Three (3) Programmable Analog Inputs (Isolated as a group) (0.025%, 12bit)
- Six (6) Programmable Digital inputs plus one (1) dedicated start interlock
- Two (2) Programmable Analog Outputs (Not Isolated) (0.1 %, 10bit)
- Three (3) Programmable Form C Relay Outputs
- Run Enable
- Adjustable Filters on Analog Inputs and Outputs
- Input Speed Signals
- Two (2) Current 0 (4) – 20 mA
- One (1) Voltage +/- 0 (2)- 10VDC
- Increase/Decrease reference Contacts
- Start/Stop
- 2 Wire (Dry Contact Closure)
- 3 Wire (Momentary Dry Contacts)
- Adjustable Current Limit
- Adjustable Torque Limit
- Nine (9) Supervision Functions
- Electronic Reverse
- Motor ID Run
- Power Loss Ride-Through
- DC Magnetizing Start (provides maximum starting torque)
- DC Hold
- Flux Braking
- Flux Optimization
- Fifteen (15) Preset Speeds
- Three (3) Critical Speed Lockout Bands
- Self-Tuning Speed Controller
- Direct Torque Control (DTCTM)
- Scalar Control
- Automatic Reset Customer Selectable
- Two (2) Independently Adjustable Accel and Decel Ramps
- Linear or Adjustable “S” Curve Accel/Decel Ramps
- Ramp or Coast to a Stop
- Maximum Frequency Programmable up to 300 Hz (scalar and DTC mode)
- Integral Programmable PID Setpoint Controller
- Mathematical Functions on Analog Reference Signals
- AC (R4 Frames & above) or DC (R2 & R3 Frames) Reactor
- Integral Brake Chopper (R2 & R3 Frames)
- Reference Trim
- Brake Control
- Master/Follower
- Programmable Fault Functions for Protection:
- AI<Min
- Panel Loss
- External Fault
- Motor Thermal Protection
- Stall
- Underload
- Motor Phase Loss
- Ground Fault
- Communications Fault
- Preprogrammed Protections:
- Overcurrent
- Short Circuit
- Overvoltage (Intermediate Circuit)
- Undervoltage (Intermediate Circuit)
- Input Phase Loss
- Output Device and Control Board Overtemperature
- DDCS Communications Card RDCO-01/-02/-03
- Analog I/O Extension Card RA10-01
- Digital I/O Extension Card RD10-01
- Pulse Encoder Interface RTAC-01
- Fieldbus Adapter Modules
- DeviceNet RDNA-01
- Profibus-DP RPBA-01
- Modbus Adapter RMBA-01
- Interbus-S RIBA-01 (not available at time of printing)
- Modbus Plus RMBP-01 (not available at time of printing)
- Control Net RCNA-01 (not available at time of printing)
- Ethernet RETA-01 (not available at time of printing)
- Dynamic Braking Choppers (R4 through R8 Frames)
- CE EMC Filters (1st and 2nd Environments)
- DriveWindow@-based Adaptive Programming Tool
- DriveWindow@-based Start-up and Programming Tool
Application Software
- Pump/Fan Control
- Extruder
- Spinning
- Traverse
- Centrifuge / Decanter
© 2004 ABB Inc. All rights reserved Specification and pricing subject to change without notice.