CSX AND CSXi CURRENT RATINGS
Model | AC53b 4.0-6:354 < 1000 meters |
AC53b 4.0-20:340 < 1000 meters |
||||||||||||||
40 °C | 50 °C | 40 °C | 50 °C | |||||||||||||
Motor HP (nominal) | Max FLC (A) | Motor HP (nominal) | Max FLC (A) | Motor HP (nominal) | Max FLC (A) | Motor HP (nominal) | Max FLC (A) | |||||||||
230 VAC | 460 VAC | 575 VAC | 230 VAC | 460 VAC | 575 VAC | 230 VAC | 460 VAC | 575 VAC | 230 VAC | 460 VAC | 575 VAC | |||||
CSX-007 | 5 | 10 | 15 | 18 | 5 | 10 | 15 | 17 | 3 | 10 | 15 | 17 | 5 | 10 | 10 | 15 |
CSX-015 | 10 | 25 | 30 | 34 | 10 | 20 | 30 | 32 | — | 20 | 25 | 30 | 10 | 20 | 25 | 28 |
CSX-018 | 15 | 30 | 40 | 42 | — | 30 | — | 40 | 10 | 25 | 30 | 36 | — | — | 30 | 33 |
CSX-022 | — | — | — | 48 | 15 | — | 40 | 44 | — | 30 | — | 40 | — | 25 | — | 36 |
CSX-030 | 20 | 40 | 50 | 60 | 20 | 40 | 50 | 55 | 15 | — | 40 | 49 | 15 | 30 | 40 | 45 |
AC53b 4.0-6:594 < 1000 meters | AC53b 4.0-20:580 < 1000 meters | |||||||||||||||
CSX-037 | 25 | — | 60 | 75 | 25 | 50 | 60 | 68 | 20 | 50 | 60 | 65 | 20 | 40 | 50 | 59 |
CSX-045 | 30 | 60 | 75 | 85 | 30 | 60 | 75 | 78 | 25 | — | 60 | 73 | 25 | 50 | 60 | 67 |
CSX-055 | — | 75 | 100 | 100 | 40 | 75 | 100 | 100 | 30 | 75 | 75 | 96 | 30 | 60 | 75 | 87 |
CSX-075 | 50 | 100 | 125 | 140 | 50 | 100 | 125 | 133 | 40 | — | 100 | 120 | 40 | 75 | 100 | 110 |
CSX-090 | 60 | 125 | 150 | 170 | 60 | 125 | 150 | 157 | 50 | 100 | 125 | 142 | 50 | 100 | 125 | 130 |
CSX-110 | 75 | 150 | 200 | 200 | — | 150 | — | 186 | 60 | 125 | 150 | 165 | — | — | 150 | 152 |
AuCom ratings are detailed using the AC53b utilisation code specified by IEC60947-4-2:
© 2015 AuCom Electronics Ltd. As AuCom is continuously improving its products it reserves the right to modify or change the specification of its products at any time without notice. The text, diagrams, images and any other literary or artistic works appearing in this brochure are protected by copyright. Users may copy some of the material for their personal reference but may not copy or use material for any other purpose without the prior consent of AuCom Electronics Ltd. AuCom endeavors to ensure that the information contained in this brochure including images is correct but does not accept any liability for error, omission or differences with the finished product.