PLEASE NOTE: Effective 2019, we no longer supply Control Techniques variable frequency drives and components. We have drives from several other manufacturers which can meet or exceed the performance characteristics of the Control Techniques line. Simply complete the form below, or contact us with the model of your current or obsolete Control Techniques drive and we’ll be glad to identify a suitable replacement.

Also, the Fincor and Saftronics lines of AC variable frequency drives, DC variable speed drives, and reduced voltage starters were once owned by Emerson but have been obsolete for several years. However, we have many years’ experience working with these drives and can quickly identify replacements capable of exceeding the quality and performance of these older drive technologies. For a suitable replacement, fill out the form below or contact us with your drive or application requirements, and we’ll handle it from there!


Unidrive SP

Go to Control Techniques, Solutions Through Innovation

Solutions Platform


Obsolete Drive Replacement RFQ -

If you need a replacement for an existing obsolete drive, complete the following form and we will send you a quote for a suitable replacement.

* Required

Is an encoder or tachometer being used for speed feedback to the drive?:
Opt-In to our e-mail list:

Unidrive SP

RATINGS, PRICES & ORDERING: SELECT MODEL BASED ON ACTUAL MOTOR FULL LOAD CURRENT

Control Techniques Unidrive SP Wall Mount AC Drives are available in six frame sizes. The Unidrive SP platform is available as wall mount drives or free standing drives.Wall Mount Drives – DriVes from 1 to 200 HP used for any AC Drive application. Shipped as drive only, and to be mounted into customer machine enclosure with other power/control components.Free Standing Drives – Pre-Engineered drive packages from 150-1 OOOhp in IP20 enclosure (standard), perfect for many standard applications (i.e. fans, pumps, conveyors, etc.)
Wall Mount Drives are available in six frame sizes

208VAC / 230VAC WALL MOUNT DRIVES RATINGS, PRICES & ORDERING

Unidrive SP
Motor HP
Continuous Output Current
Peak Output Current
Price
208/230VAC
Normal Duty
Order Code
Frame
HP @ 230V
IN (A)
(A)
 
SP1201-XXX
 
 
 
1
1.5
5.2
5.7
CALL
SP1202-XXX
2
6.8
7.5
CALL
SP1203-XXX
3
9.6
10.6
CALL
SP1204-XXX
3
11
12.1
CALL
SP2201-XXX
 
 
2
5
15.5
17.0
CALL
SP2202-XXX
7.5
22
24.2
CALL
SP2203-XXX
10
28
30.8
CALL
SP3201-XXX
 
3
15
42
46.2
CALL
SP3202-XXX
20
54
59.4
CALL
SP4201-XXX
4
25
68
74.8
CALL
SP4202-XXX
30
80
88
CALL
SP4203-XXX
40
104
114.4
CALL
(Call Joliet Technologies for prices)
Unidrive SP
Motor HP
Continuous Output Current
Peak Output Current
Peak Output Current
 
Price
208/230VAC
Heavy Duty
Order Code
Frame
HP @ 230V
IH (A)
Open loop (A)
Closed loop (A)
 
SP1201-XXX
 
 
 
1
1
4.3
6.4
7.5
CALL
SP1202-XXX
1.5
5.8
8.7
10.1
CALL
SP1203-XXX
2
7.5
11.3
13.1
CALL
SP1204-XXX
4
10.6
15.9
18.5
CALL
SP2201-XXX
 
 
2
4
12.6
18.9
22.0
CALL
SP2202-XXX
5
17
25.5
29.7
CALL
SP2203-XXX
7.5
25
37.5
43.7
CALL
SP3201-XXX
 
3
10
31
46.5
54.2
CALL
SP3202-XXX
15
42
63
73.5
CALL
SP4201-XXX
4
20
56
84
98
CALL
SP4202-XXX
25
68
102
119
CALL
SP4203-XXX
30
80
120
140
CALL
(Call Joliet Technologies for prices)

Note: Motor horsepower ratings are based on typical motor current ratings. Actual motor currents should be checked before selecting a particular drive. For some high efficiency motors, the required full load motor current may allow the selection of a smaller drive than is indicated in the chart. The same consideration would also apply for motors with less common power or voltage ratings.

Normal Duty
Suitable for most applications, current overload is set at 110% for 60 seconds. Where motor rated current is less than the drive rated continuous current, higher over loads are achieved.
Heavy Duty
Suitable for demanding applications, current overload is set at up to 175% for 40 seconds. Where motor rated current is less than the drive rated continuous current, higher overloads (200% or greater) are achieved.

380VAC / 480VAC WALL MOUNT DRIVES RATINGS, PRICES & ORDERING

Unidrive SP
Motor HP
Continuous Output Current
Peak Output Current
 
Price
380/480VAC
Normal Duty
Order Code
Frame
HP @ 460V
IN (A)
(A)
 
SP1401-XXX
1
1.5
2.8
3.0
CALL
SP1402-XXX
2
3.8
4.1
CALL
SP1403-XXX
3
5
5.5
CALL
SP1404-XXX
5
6.9
7.5
CALL
SP1405-XXX
5
8.8
9.6
CALL
SP1406-XXX
7.5
11
12.1
CALL
SP2401-XXX
2
10
15.3
16.8
CALL
SP2402-XXX
15
21
23.1
CALL
SP2403-XXX
20
29
31.9
CALL
SP2404-XXX
20
29
31.9
CALL
SP3401-XXX
3
25
35
38.5
CALL
SP3402-XXX
30
43
47.3
CALL
SP3403-XXX
40
56
61.6
CALL
SP4401-XXX
4
50
68
74.8
CALL
SP4402-XXX
60
83
91.3
CALL
SP4403-XXX
75
104
114.4
CALL
SP5401-XXX
5
100
138
151.8
CALL
SP5402-XXX
150
168
184.8
CALL
SP6401-XXX
6
150
202
222.2
CALL
SP6402-XXX
200
236
259.6
CALL
(Call Joliet Technologies for prices)
Unidrive SP
Motor HP
Continuous Output Current
Peak Output Current
Peak Output Current
Price
380/480VAC
Heavy Duty
Order Code
Frame
HP @ 460V
IH (A)
Open loop (A)
Closed loop (A)
 
SP1401-XXX
1
1
2.1
3.1
3.6
CALL
SP1402-XXX
2
3
4.5
5.2
CALL
SP1403-XXX
3
4.2
6.3
7.3
CALL
SP1404-XXX
4
5.8
8.7
10.1
CALL
SP1405-XXX
5
7.6
11.4
13.3
CALL
SP1406-XXX
5
9.5
14.2
16.6
CALL
SP2401-XXX
2
10
13
19.5
22.7
CALL
SP2402-XXX
10
16.5
24.7
28.8
CALL
SP2403-XXX
15
25
34.5
40.2
CALL
SP2404-XXX
20
29
43.5
50.7
CALL
SP3401-XXX
3
25
32
48
56
CALL
SP3402-XXX
30
40
60
70
CALL
SP3403-XXX
30
46
69
80.5
CALL
SP4401-XXX
4
50
60
90
105
CALL
SP4402-XXX
60
74
111
129.5
CALL
SP4403-XXX
75
96
144
168
CALL
SP5401-XXX
5
100
124
186
217
CALL
SP5402-XXX
125
156
234
273
CALL
SP6401-XXX
6
150
180
231
269
CALL
SP6402-XXX
150
210
270
315
CALL
(Call Joliet Technologies for prices)

Unidrive SP Wall Mounted Drives Order String Control Techniques Unidrive SP Wall Mounted AC Drives Order Sting.

575VAC WALL MOUNT DRIVES RATINGS, PRICES & ORDERING

Unidrive SP
Motor HP
Continuous Output Current
Peak Output Current
Price
575VAC
Normal Duty
Order Code
Frame
HP @ 575V
IN (A)
(A)
 
SP3S01-XXX
3
5
5.4
5.9
CALL
SP3S02-XXX
5
6.1
6.7
CALL
SP3S03-XXX
7.5
8.4
9.2
CALL
SP3S04-XXX
10
11
12.1
CALL
SP3S0S-XXX
15
16
17.6
CALL
SP3S06-XXX
20
22
24.2
CALL
SP3S07-XXX
25
27
29.7
CALL
SP4603-XXX
4
30
36
39.6
CALL
SP4604-XXX
40
43
47.3
CALL
SP4605-XXX
50
52
57.2
CALL
SP4606-XXX
60
62
68.2
CALL
SP5601-XXX
5
75
84
92.4
CALL
SPS602-XXX
100
99
108.9
CALL
SP6601-XXX
6
125
125
137.5
CALL
SP6602-XXX
150
144
158.4
CALL
(Call Joliet Technologies for prices)
Unidrive SP
Motor HP
Continuous Output Current
Peak Output Current
Peak Output Current
Price
575VAC
Heavy Duty
Order Code
Frame
HP @ 575V
IH (A)
Open loop (A)
Closed loop (A)
 
SP3S01-XXX
3
3
4.1
6.1
7.1
CALL
SP3S02-XXX
5
5.4
8.1
9.4
CALL
SP3S03-XXX
5
6.1
9.1
10.6
CALL
SP3S04-XXX
7.5
9.5
14.2
16.6
CALL
SP3S0S-XXX
10
12
18
21
CALL
SP3S06-XXX
15
18
27
31.5
CALL
SP3S07-XXX
20
22
33
38.5
CALL
SP4603-XXX
4
25
27
40.5
47.3
CALL
SP4604-XXX
30
36
54
63
CALL
SP4605-XXX
40
43
64.5
75.3
CALL
SP4606-XXX
50
52
78
91
CALL
SP5601-XXX
5
60
62
93
108.5
CALL
SPS602-XXX
75
84
126
147
CALL
SP6601-XXX
6
100
100
130
150
CALL
SP6602-XXX
125
125
162.5
187.5
CALL
(Call Joliet Technologies for prices)

690VAC WALL MOUNT DRIVES RATINGS, PRICES & ORDERING

Unidrive SP
Motor HP
Continuous Output Current
Peak Output Current
Price
690VAC
Normal Duty
Order Code
Frame
HP @ 690V
IN (A)
(A)
 
SP4601-XXX
4
25
22
24.2
CALL
SP4602-XXX
30
27
29.7
CALL
SP4603-XXX
40
36
39.6
CALL
SP4604-XXX
50
43
47.3
CALL
SP460S-XXX
60
52
57.2
CALL
SP4606-XXX
75
62
68.2
CALL
SP5601-XXX
5
100
84
92.4
CALL
SP5602-XXX
125
99
108.9
CALL
SP6601-XXX
6
150
125
137.5
CALL
SP6602-XXX
175
144
158.4
CALL
(Call Joliet Technologies for prices)
Unidrive SP
Motor HP
Continuous Output Current
Peak Output Current
Peak Output Current
Price
690VAC
Heavy Duty
Order Code
Frame
HP @ 690V
IH (A)
Open loop (A)
Closed loop (A)
 
SP4601-XXX
4
20
19
28.5
33.3
CALL
SP4602-XXX
25
22
33
38.5
CALL
SP4603-XXX
30
27
40.5
47.3
CALL
SP4604-XXX
40
36
54
63
CALL
SP460S-XXX
50
43
55.7
75.2
CALL
SP4606-XXX
60
52
67.6
91
CALL
SP5601-XXX
5
75
62
93
108.5
CALL
SP5602-XXX
100
84
128
147
CALL
SP6601-XXX
6
125
100
128
149
CALL
SP6602-XXX
150
125
160
187
CALL
(Call Joliet Technologies for prices)

Note: Motor horsepower ratings are based on typical motor current ratings. Actual motor currents should be checked before selecting a particular drive. For some high efficiency motors, the required full load motor current may allow the selection of a smaller drive than is indicated in the chart. The same consideration would also apply for motors with less common power or voltage ratings.

Normal Duty
Suitable for most applications, current overload is set at 110% for 60 seconds. Where motor rated current is less than the drive rated continuous current, higher over loads are achieved.
Heavy Duty
Suitable for demanding applications, current overload is set at up to 175% for 40 seconds. Where motor rated current is less than the drive rated continuous current, higher overloads (200% or greater) are achieved.

Information provided by Control Techniques, a world leader in the design, production and marketing of electronic drives for the control of electric motors.