PLEASE NOTE: Effective 2019, we no longer supply Control Techniques variable frequency drives and components. We have drives from several other manufacturers which can meet or exceed the performance characteristics of the Control Techniques line. Simply complete the form below, or contact us with the model of your current or obsolete Control Techniques drive and we’ll be glad to identify a suitable replacement.
Also, the Fincor and Saftronics lines of AC variable frequency drives, DC variable speed drives, and reduced voltage starters were once owned by Emerson but have been obsolete for several years. However, we have many years’ experience working with these drives and can quickly identify replacements capable of exceeding the quality and performance of these older drive technologies. For a suitable replacement, fill out the form below or contact us with your drive or application requirements, and we’ll handle it from there!
- Overview / Typical Applications
- Features
- Ratings, Prices & Ordering – Wall Mount Drives
- Ratings, Prices & Ordering – Free Standing Cubicle Drives
- Unidrive SP Regen Mode
- Terminal Diagram and Terminal Description
- Specifications and Dimensions
- Options – Overview / Options at-a-Glance
- Operator Interface
- Power Accessories
- Option Modules – Feedback Modules
- Option Modules – Input / Output Modules
- Option Modules – Application / Programming Modules
- Option Modules – Communication Modules
- Drive Configuration and Programming
- Software Overview – Application Programming Software
- Pre-packaged Solutions for Unidrive SP
SPECIFICATIONS
Environment | |
Ambient Operating Temperature | 0° to 40°C (32° to 104°F) 0° to 50°C (32° to 122°F) with derating |
Cooling method | Forced convection |
Humidity | 95% maximum non-condensing at 40°C (104°F) |
Storage Temperature | -40° to 50°C (-40° to 140°F) |
Altitude | 0 to 3000m (9,900 ft). Derate 1% per 100m (328 ft) between 1000m (3280 ft) and 3000m (9,900 ft). |
Vibration | Tested in accordance with IEC 68-2-34 |
Mechanical Shock | In accordance with IEC 68-2-27 |
Enclosure | NEMA 1 (IP 21), NEMA 12 (IP 54) through panel mounting |
Electromagnetic Immunity | In compliance with IEC801 and EN50082-2, and complies with EN61800-3 with built-in filter |
Electromagnetic Emissions | In compliance with EN50081-2 when the recommended RFI filter is used and EMC installation guidelines are followed |
AC Supply Requirements | |
Voltage | 200 to 240 VAC +10% 380 to 480 VAC +10% 500 to 575 VAC +10% 500 to 690 VAC +10% |
Phase | 3Ø |
Phase Imbalance Tolerance | 2% negative phase sequence (equivalent to 3% voltage imbalance between phases) |
Frequency | 48 to 65 Hz |
Input Displacement Power Factor | 0.93 |
Control | |
Carrier Frequency | 3, 4, 6, 8, 12, 16kHz |
Output Frequency | 0 to 3000Hz (Open loop) |
Output Speed | 0 to 40,000 RPM (Closed loop) |
Frequency Accuracy | +0.01% of full scale |
Frequency Resolution | 0.001 Hz |
Analog Input Resolution | 10 Bit + sign (Qty 2); 16 Bit + sign (Qty 1) |
Serial Communications | 2 or 4-wire RS485. Protocol is ANSI x 3.28-2.5-A4, or Modbus RTU Baud rate 300 to 115,200. |
Braking | DC injection braking (stopping and holding) standard. Dynamic braking transistor standard. |
Control Power Ride Through | Up to 1 second depending on inertia and decel time |
Protection | |
DC Bus Undervoltage Trip | 175 / 350 / 435 VDC (approximately 124 / 247 / 307 VAC line voltage) |
DC Bus Overvoltage Trip | 415 / 830 / 990 VDC (approximately 293 / 587 / 700 VAC line voltage) |
MOV Voltage Transient Protection | 160 Joules, 1400 VDC clamping (Line to line and line to ground) |
Drive Overload Trip | Current overload value is exceeded. Programmable for Normal Duty or Heavy Duty. Open loop or Closed loop operation. |
Instantaneous Overcurrent Trip | 225% of drive rated current |
Phase Loss Trip | DC bus ripple threshold exceeded |
Overtemperature Trip | Drive heatsink, cntrol board, and option module(s) mounting |
Short Circuit Trip | Protects against output phase to phase fault |
Ground Fault Trip | Protects against output phase to ground fault |
Motor Thermal Trip | Electronically protects the motor from overheating due to loading conditions |
Approvals & Listings | |
UL, cUL | UL File #E171230 |
IEC | Meets IEC Vibration, Mechanical Shock and Electromagnetic Immunity Standards |
CE | Designed for marking |
NEMA | NEMA 1 enclosure type |
VDE | Meets VDE Electromagnetic Emissions Standards |
ISO 9002 | Certified Manufacturing Facility |
DIMENSIONS
Frame Size |
H |
W |
D |
Weight |
||||
in |
mm |
in |
mm |
in |
mm |
lb |
kg |
|
1 |
15.20 |
386 |
3.93 |
100 |
8.62 |
219 |
12.8 |
5.8 |
2 |
15.32 |
389 |
6.10 |
155 |
8.62 |
219 |
15.4 |
7.0 |
3 |
15.32 |
389 |
9.84 |
250 |
10.23 |
260 |
33.1 |
15.0 |
4 |
21.53 |
547 |
12.20 |
310 |
11.73 |
298 |
66.1 |
30.0 |
5 |
33.75 |
857 |
12.20 |
310 |
11.73 |
298 |
165.3 |
75.0 |
6 |
46.02 |
1169 |
12.20 |
310 |
11.73 |
298 |
165.3 |
75.0 |
For through-panel mounting dimensions or dimensions of size 6, 7, 8 and 9 Free Standing Drives, contact your local Drive Center
Information provided by Control Techniques, a world leader in the design, production and marketing of electronic drives for the control of electric motors.