PLEASE NOTE: Effective 2019, we no longer supply Control Techniques variable frequency drives and components. We have drives from several other manufacturers which can meet or exceed the performance characteristics of the Control Techniques line. Simply complete the form below, or contact us with the model of your current or obsolete Control Techniques drive and we’ll be glad to identify a suitable replacement.

Also, the Fincor and Saftronics lines of AC variable frequency drives, DC variable speed drives, and reduced voltage starters were once owned by Emerson but have been obsolete for several years. However, we have many years’ experience working with these drives and can quickly identify replacements capable of exceeding the quality and performance of these older drive technologies. For a suitable replacement, fill out the form below or contact us with your drive or application requirements, and we’ll handle it from there!


Saftronics

Saftronics Two Year Warrenty

Obsolete Drive Replacement RFQ -

If you need a replacement for an existing obsolete drive, complete the following form and we will send you a quote for a suitable replacement.

* Required

Is an encoder or tachometer being used for speed feedback to the drive?:
Opt-In to our e-mail list:

(Obsolete) Saftronics CV10 Compact Vector AC Drives
(Obsolete Saftronics PC10 Mini Vector AC Drives)
(Obsolete FINCOR Series 5750)

Standard Specifications

Environmental Conditions

Enclosures Protected Chassis (IP20) and NEMA 1

Installation Location NEMA 1 Intended for indoor use only, less than 1,000 meters (3,300 feet) elevation, not in contact with corrosive gas, oil mist, dust or direct sunlight.Free from corrosive gases, flammable gases, oil mist, dust and direct sunlight. Indoor use only.

Altitude 1000m or less. Applicable to 3000m with power derating (-10%/1000m)

Ambient Temperature 10°C to +50°C (+14°F to 122°F)

Ambient Humidity 5 to 95% RH (non-condensing)

Vibration 1 G (9.8 m/s2)

Storage Condition Temperature: -25°C to +65°C (-4°F to 149°F)
Humidity: 5 to 95% RH (non-condensing)

Input

Rated Input AC Voltage 200 to 230Vac 50/60 Hz, single and 3-phase (1/2 to 10 hp)
380 to 480Vac 50/60 Hz, 3-phase (1 to 15 hp)
Voltage: -15% to +10%; voltage unbalance: within 3%; frequency: + 5%

Output

Setting Maximum frequency: 50 to 650 Hz
Base frequency: 25 to 650 Hz
Carrier frequency: 0.75 to 16kHz

Speed Control Accuracy +/- 0.5% (Sensorless Vector Control)

Setting Resolution Digital setting: 0.01 Hz The setting resolution above 100Hz is 0.1 hz when controlled form the keypad and 0.01 Hz when controlled via computer (PC) or programmable controller (PLC).
Analog: 0.06Hz/60hz(10bits)

Control

Control Method
V/f control (sinusoidal PWM control)
17 patterns
1 programmable
Sensorless Vector Control (sinusoidal PWM control)
Vector Control Mode Heavy Duty
Vector Control Mode Normal Duty (Fan and Pump type loads)

Starting Torque 150% at 1 Hz (Sensorless Vector Control)

Operation Method Keypad operation: RUN or STOP key
Digital input signal: Forward/Reverse command, Coast-to-Stop command, etc.
Link operation: RS-232, RS485, Profibus-DP, DeviceNet™, Ethernet

Frequency Setting Keypad operation: UP or DOWN keys
Keypad operation: Potentiometer
External potentiometer of 1 to 5k ohm
Analog input: 0 to 10 Vdc (0 to 5 Vdc) , 4 to 20 mA dc
Multistep frequency: up to 7 different frequencies can be selected by digital input signal
Link operation: RS-232, RS485, Profibus-DP, DeviceNet™, Ethernet

Digital Inputs 6 Multifunction inputs
Sink or Source Multifunction input

Analog Inputs 2 Analog inputs
6 Functions for the multifunction analog input

Acceleration/Deceleration Time 0.01 to 3600s (independently adjustable acceleration and deceleration, 2 different times are selectable)

Voltage/Frequency
(V/F) Characteristics
Adjustable at base and maximum frequency: 320 to 480V (460V series). 80 to 240V (230V series)

Restart After Momentary
Power Failure
Drive restarts without causing the motor to stop if the automatic restart is specified for the drive

Frequency Upper/Lower Limits Upper and lower limits can be preset

Bias Frequency Bias frequency can be preset (0 to 650 Hz)

Jump Frequency Control Jump frequency (3 points) and its common jump hysteresis width (0 to 30 Hz) can be preset

Protection

Overload Protects the drive by electronic thermal and detection of drive temperature

Overvoltage Detects dc link circuit overvoltage to stop drive (460V series: 820 Vdc, 230V series: 410 Vdc)

Overheating Protects the drive by detection of drive temperature

Motor Overload Electronic thermal overload relay can be selected for standard motor or drive motor

Options

Standard DB Resistors, LCD keypad, Program Copy Module

Communications RS-232, RS-485, Profibus-Dp, DeviceNet™, Ethernet