PLEASE NOTE: Effective 2019, we no longer supply Control Techniques variable frequency drives and components. We have drives from several other manufacturers which can meet or exceed the performance characteristics of the Control Techniques line. Simply complete the form below, or contact us with the model of your current or obsolete Control Techniques drive and we’ll be glad to identify a suitable replacement.

Also, the Fincor and Saftronics lines of AC variable frequency drives, DC variable speed drives, and reduced voltage starters were once owned by Emerson but have been obsolete for several years. However, we have many years’ experience working with these drives and can quickly identify replacements capable of exceeding the quality and performance of these older drive technologies. For a suitable replacement, fill out the form below or contact us with your drive or application requirements, and we’ll handle it from there!


Saftronics  

Obsolete Drive Replacement RFQ -

If you need a replacement for an existing obsolete drive, complete the following form and we will send you a quote for a suitable replacement.

* Required

Is an encoder or tachometer being used for speed feedback to the drive?:
Opt-In to our e-mail list:

(Obsolete) Saftronics GP10 – General Purpose Open Loop Vector AC Drive (Obsolete FINCOR Series 5700)

Standard Specifications

Environmental Conditions

Enclosure NEMA 1 Standard (NEMA 4, NEMA 12), Open (IPOO)

Installation Location: NEMA 1 Intended for indoor use only, less than 1000 meters (3300 feet) elevation, not in contact with corrosive gas, oil mist, dust or direct sunlight.
  NEMA 4 Intended for use indoors to protect the enclosed equipment against splashing water, seepage of water, falling or hose directed water and severe external condensation. Installation should be less than 1000 meters (3300 feet) elevation, not in contact with corrosive gas, oil mist or direct sunlight.
  NEMA 12 Intended for indoor use only, less than 1000 meters (3300 feet) elevation, not in contact with corrosive gas, oil mist, dust or direct sunlight.

Stored Temperature -25 to + 65°C (-13° to + 149°F)

Ambient Temperature -10 to 50°C (+ 14 to 122°F) Ventilating covers must be removed under conditions exceeding +40°C (+ 104°F) for models rated at 30 Hp or less.

Humidity 5% to 95% relative humidity (non-condensing).

Vibration 3mm peak from 2-9 Hz, 9.8 m/s2 from 9-20 Hz, 2 m/s2 from 20-55 Hz, 2 m/s2 from 55-200 Hz.

Cooling Method 1 Hp and below – Convection Above 1 Hp – Fan-cooled

Output 

Rated Output Voltage 230 VAG, 3-Phase, 200V/50 Hz or 3-Phase, 200V, 220V, 230V/60 Hz 460 VAG, 3-Phase, 380V, 400V, 415V, 440V, 50 Hz or 3-Phase 380V, 400V, 440V, 460V, 60 Hz

Frequency Range 0.1 to 120Hz

Overload Current Rating 110% of drive’s rated current for 1 min. (ND) 150% of drives rated current for 1 min (HD)

Power Supply

Rated Input AC Voltage 230 VAG: 200 to 230 VAG 50/60 Hz, 3 phase (1/4 to 30 Hp) 230 VAG: 200 to 220 VAC/50 Hz, 200 to 230 VAC/60 Hz, 3 phase (40 Hp or more) 460 VAG: 380 to 480 VAG 50/60 Hz, 3 phase (1/2 to 30 Hp) 460 VAG: 380 to 440 VAC/50 Hz, 380 to 480 VAC/60 Hz, 3 phase (40 Hp or more) Voltage: +10%, -15%; Voltage Unbalance – Within 3% Frequency: +/-5%

Control System Sinusoidal PWM Control (V/Hz Control, Dynamic Torque Vector Control)

Momentary Voltage Dip 230 VAG: When the input voltage is 165 VAG or more, the drive can be operated continuously. 460 VAG: When the input voltage is 310 VAG or more, the drive can be operated continuously. When the input voltage drops below 165/310 VAG from rated voltage, the drive can be operated for 15ms. The smooth recovery method is selectable.

Control

Starting Torque 180% above 30 HP, 200% below 30 HP with Dynamic Torque selected. (Heavy Duty)

Carrier Frequency 0.75-15 kHz -30 Hp or less 0.75-10 kHz -40 Hp to 100 Hp 0.75- 6 kHz -125 Hp or more

Frequency Setting Resolution Analog: 1/3000 of max. frequency (0.02 Hz/60 Hz; 0.05 Hz/150 Hz) Digital: 0.01 Hz (max. frequency up to 99.99 Hz); 0.1 Hz (max. frequency of 100 Hz or more)

Output Frequency Accuracy (Stability) Analog setting: :to.2% or less of max. frequency (@ 25:t 10°C) Digital setting: :to.O1 % or less of max. frequency (@ -10 to +50°C)

Voltage/Frequency Characteristics (V /F) Output voltage at base frequency can be adjusted separately, such as 80 to 240 V (230V series) or 320 to 480V (460V series)

Torque Boost Auto: Optimum control corresponding to the load torque 0.0 setting Manual: 0.1 to 20.0 code setting for constant/variable torque load

A cceleration/D ecel e ratio n Characteristics 0.01 to 3600 seconds (Four acceleration/deceleration time settings are possible independent of each other by selecting digital input signals

Operating Sound Selection The drive carrier frequency can be changed to reduce audible noise and sound tone.

Analog/Pulse Output Scale calibration of externally connected analog meter (10 VDC, 0-200% gain setting and pulse output (300 to 6,000 P/S)

Data Protection Data lock is possible to ensure that the data codes are not changed.

Pattern Operation Seven independent stages (frequency up to 120 Hz, duration up to 6,000 seconds each).
Configuration: Single cycle Repeating cycling Single cycle with continuous last setting speed

Momentary Power Loss Ride Thru Six selections available. (Refer to Power Supply Specification.)

High/Low Limiter Output frequency upper and lower range limit 0 to 120 Hz; 1 Hz step settings.

Bias Magnitude of the zero offset can be set from -120 to 120 Hz (0.1 Hz steps.)

Gain Output frequency gain corresponding to the reference signal can be set from 0 to 200% (0.1 % steps.)

Programmable Jump Frequency Three selectable frequencies can be set to avoid a mechanical resonant point. Width is adjustable from 0 to 120 Hz (1 Hz steps.)

Slip Compensation Control Maintains motor at constant speed with load fluctuations. Adjustable from 0.00 Hz to 15.00 Hz.

Torque Limit Control Output torque can be controlled within a range of 20% to 150% (1 % steps).

15 Step Preset Speed 15 programmable preset speeds selectable by 4 contact closures.

PID Normal or Inverse operation can be selected.

Momentary or Maintained Contact Operation Selection between the maintained contact operation/stop command (2wire operation) or the momentary contact (3-wire operation).

Terminal Function Change Multi-Use terminals changed via Function Code settings. X1 to X9 inputs; Y1 to Y 4 transistor output and Y5 relay output.

Line to Drive Transition Logic Provides the logic for transferring a motor from AC line to drive operation in a bypass system.

Sensorless Vector Control (Dynamic Torque Vector Control) Improves torque characteristics throughout speed range. Improves speed regulation.

Operation

Frequency Reference Signal Speed potentiometer: a to +10 VDC, 10 to a VDC 4 to 20 mA, 20 to 4mA a to +10 VDC

Digital Input Signal Multi-step frequency selection (1 to 15 steps) Acceleration and deceleration time selection (3 steps) Self-Hold selection (HLD) Coast-to-Stop command (BX) Alarm Reset (RST) External Alarm (THR) Jogging (JOG) Frequency setting 2 / Frequency setting 1 (Hz2/ Hz1) Motor 2 / Motor 1 (M2 / M1) DC injection brake command (DCBRK) Torque limit 2 / Torque limit 1 (TL2 / TL 1) Switching operation from line to drive (50 Hz) (SW50) Switching operation from line to drive (60 Hz) (SW60) UP command (UP) DOWN command (DOWN) Edit permission command (data change permission) (WE-KP) PID control cancellation (Hz/PI D) Normal/inverse switching (Terminals 12 and C1) (lVS) Interlock (52-2) (IL) Link operation selection (Standard: RS485, Option: BUS) (LE) Universal DI (U-DI) Pick up start mode (STM) Timed alarm stop command (STOP 1) Timed alarm stop command with Deceleration time 4 (STOP 4)

Digital Output Signals One Dry, Form C “fault” output contact rated 250 VAG, 0.3 amp. One auxiliary relay contact rated 250 VAG, 0.3 amp Four Open collector outputs each rated 27 VDC, 50 mA from external power. One relay and four open collector output can be configured to provide one of the following functions:

  • Operating (RUN)
  • Frequency arrival (FAR)
  • Frequency detection (FDT1)
  • Stopping due to overvoltage (LV)
  • Torque polarity detection (B/D)
  • Torque limiting (TL)
  • Restarting after momentary power failure (IPF)
  • Overload- early warning (OLl)
  • During Keypad panel operation (KP)
  • Drive stopping (STP)
  • Ready for operation (ROY)
  • Operation switching between line and drive (SW88)
  • Operation switching between line and drive (SW52-2)
  • Operation switching between line and drive (SW52-1
  • Motor 2 switching (SWM2)
  • Terminal P\I.. function (AX)
  • Pattern operation stage change (TU)
  • Pattern operation cycle operation completed (TO)
  • Pattern operation stage number (STG1)
  • Pattern operation stage number (STG2)
  • Pattern operation stage number (STG4)
  • Alarm detail (AL 1)
  • Alarm detail (AL2)
  • Alarm detail (AL4)
  • Alarm detail (AL8)
  • Cooling fan operating (FAN)
  • Retry function operating (TRY)
  • Universal DO (U-DO)
  • Heatsink overheat- early warning (OH)
  • 2nd frequency level detection (FDT2)
  • 2nd OL level- early warning (OL2)
  • Terminal C1 off signal (C1OFF)

Protective Functions
  • Overcurrent
  • Ground Fault
  • Overvoltage
  • Undervoltage
  • Input Phase Loss
  • Overheating of Heatsink
  • External Alarm
  • Overheating Internally
  • Overheating of Braking Resistor
  • Motor 1 Overload
  • Motor 2 Overload
  • Inverter Overload
  • Blown Fuse
  • Memory Error
  • Keypad Panel Communication Error
  • CPU Error
  • Option Error
  • Operating Error
  • Output Wiring Error
  • Modbus RTU Error

Keypad Features Digital Display – 4 digit LED Six Languages (English, German, French, Spanish, Italian, Japanese) Graphic Display – LCD, with backlight Nine program menu includes data copy function

Keypad Display
  • Output frequency 1 (before slip compensation)
  • Output frequency 2 (after slip compensation)
  • Setting Frequency
  • Output Current
  • Output Voltage (specified value)
  • Synchronous Speed
  • Une Speed
  • Load Rotation Speed
  • Torque Calculation Value
  • Power Consumption
  • PID Setting Value
  • PID Remote Setting Value
  • PID Feedback Value
  • Program Menu Mode

Keypad Display in Program Mode Function Code and setting data displayed (see Operation Panel paragraph

RS485 RTU Serial Communication
  • Physical Level
  • Transmission Distance
  • Number of nodes
  • Transmission Speed
  • Transmission mode
  • Transmission protocol
  • Character code
  • Character length
  • Error check
EIA/RS485 500m max. 32 total 19200, 9600, 4800, 2400 (bits/s) Half duplex Modbus RTU Binary 8 bits CRC

Charge Lamp (LED) Lights when DC Link capacitor voltage is present.

Mounting Clearance