Saftronics

Obsolete Drive Replacement RFQ -

If you need a replacement for an existing obsolete drive, complete the following form and we will send you a quote for a suitable replacement.

* Required

Is an encoder or tachometer being used for speed feedback to the drive?:
Opt-In to our e-mail list:

(Obsolete) Saftronics VG10 – Dynamic Torque Vector AC Drive
(Obsolete FINCOR Series 6600)

Options & Accessories

Description Part Number Price
Keypad Extension Cable – 2m Straight 018-G102 $ CALL
Keypad Extension Cable – 5m Coiled 018-G105 $ CALL
Keypad Extension Cable – 10m Coiled 018-G1010 $ CALL
Saflink Kit – Hardware & Software 046-VG10SL $ CALL
Saflink – Software only 046-3022 $ CALL
Palm Pilot Saflink Kit 046-7030 $ CALL
SR10 Highspeed Wireless Link for VG10 046-9029 $ CALL
Relay Output Card SOPCG11SRY $ CALL
Digital Interface Card SOPCG11SDIO $ CALL
Analog Interface Card SOPCG11SAIO $ CALL
Profibus DP Serial Communication SOPCG11SPDP $ CALL
DeviceNet Serial Communication SOPCG11SDEV $ CALL
Modbus Plus Serial Communication SOPCG115MBP $ CALL
Interbus S Serial Communication SOPCG11SIBS $ CALL
LONWorks Communication SOPCG11SLON $ CALL
Custom I/0 Card (Isolation Card) SOPCG11SCIO $ CALL
MetaSys N2 Communication SOPCG11SMN2 $ CALL
Genius Communication SHE300GEN150 $ CALL
Siemens Serial Communication SOPCG11SP1 $ CALL
SF10 Ethernet Module 046-7034 $ CALL
120/24V I/P Board with 4 Relays (External Mount) 043-0303 $ CALL
120/24V I/P Board 100-0171-01 $ CALL
Pressure Transducer Card with 4-20mA Outputs 100-0163-01 $ CALL
Sleep Function / Reference Loss Card 100-0175-01 $ CALL
HMI Pump Controller 043-0906 $ CALL
PGX Encoder Feedback Card 100-0170-01 $ CALL
PG Feedback Card with 2 analog outputs 100-0164-01 $ CALL
PG Feedback Card (12/15V); A, B Signal) SOPCG11SPG $ CALL
PG Feedback Card (5V, A, A-, B, B- Signal) SOPCG11SPG2 $ CALL
Synchronized Operation Card SOPCG11SSY $ CALL
Keypad Mounting Kit Nema 1/12 with 2 Meter Cable 043-1010-2 $ CALL
Keypad Mounting Kit Nema 1/12 with 5 Meter Cable 043-1010-5 $ CALL
Keypad Mounting Kit Nema 1/12 with 10 Meter Cable 043-1010-10 $ CALL
Keypad Mounting Kit Nema 4/3R with 2 Meter Cable 043-1012-2 $ CALL
Keypad Mounting Kit Nema 4/3R with 5 Meter Cable 043-1012-5 $ CALL
Keypad Mounting Kit Nema 4/3R with 10 Meter Cable 043-1012-10 $ CALL
Heatsink Mounting Kit 1/4, 1/2, 1 HP, Heatsink through Panel 043-0901 $ CALL
Heatsink Mounting Kit 2-5HP Heatsink through Panel 043-0902 $ CALL
Heatsink Mounting Kit 7.5 -10HP HD 043-0903 $ CALL
Heatsink Mounting Kit 15-30HP HD 043-0904 $ CALL
Contact Joliet Technologies for price and availability of these units

Options & Accessories

The drive supports two internally mounted cards. One option card is mounted under the main cover (location A) and the other option card is mounted in a special adapter under the keypad (location B), refer to option card instruction manual for mounting information. There are two different types of option cards, Type 1 and Type 2. Two Type 1 or two type 2 cards cannot be used at the same time. Combinations of Type 1 and Type 2 may be used as long as there is only one per mounting location and follows the chart below. Each option card must be mounted in the designated location. The chart below lists the option card, their type and their mounting location.

Name Type Loc 2nd Option
Type/Loc
Function
SOPCG11SRY
(Relay output card)
1 A 2/B – Relay output card
The transistor output from the drive controls output terminals Y1 through Y4 which are converted to the relay outputs (1 SPDT, 3A. 250 VAG).
SOPCG11SDIO
(Digital interface card)
2 A None – Frequency setting by binary code (max. 16 bits)
– Monitoring (8 bits) of frequency, output current, and output voltage
SOPCG11SAIO
(Analog interface card)
2 A None – Auxiliary input for analog frequency setting (0 to +1  10 V)
– Monitoring of drive output frequency, current, and torque in analog voltage
SOPCG11SPG
(VG1 0 only)
(PG Feedback Card)
1 A 2/B – This will enable vector control by pulse generator feedback signal
– Proportional operation, tuning operation (12/15 V; A, B Signal)
SOPCG11SPG2
(VG10 only)
(PG Feedback Card)
1 A 2/B – This will enable vector control by pulse generator feedback signal
– Proportional operation, tuning operation (5V; A, A-, B, B- Signals)
SOPCG11SCIO
(Interface card)
2 A 2/B – 115 VAC Controi input, an isolation amplifier, relay output PG encoder
SOPCG11SLON
(Communication Card)
2 B 1/A – Serial communication card for LonWorks
SOPCG11SPDP
(Communication Card)
2 B 1/A – Serial communication card for Profibus-DP
SOPCG11SDEV
(Communication Card)
2 B 1/A – Serial communication card for Device Net
SOPCG11SCOP
(Communication Card)
2 B 1/A – Serial communication card for CAN
SOPCG11SMBP
(Communication Card)
2 B 1/A – Serial communication card for Modbus Plus
SOPCG11SIBS
(Communication Card)
2 B 1/A Serial communication card for Interbus-S
SHE300GEN150
(Communication Card)
2 B 1/A – Serial communication card for Genius
SOPCG11SSY
(VG10 only)
(Operation Card)
1 A 2/B – Two motors are driven synchronously
100-0164-01
(PG Feedback Card / Analog Card)
1 A 2/B – To perform speed control by interfacing with a pulse generator encoder and to provide two precision analog outputs that can represent two types of data (output frequency, output current, etc.)
100-0170-01
(PGX Feedback Card)
1 A 2/B – To perform speed control by interfacing with a pulse  generator (5/12V; A, A-, B, B- Signals)
SOPG11SP1
(Communication Card)
2 B 1/A – Serial communication card for Siemens
100-0175-01
(Sleep Function)
2 A None – Monitors 3 Independent lIP functions and provides 3 for MC Relay outputs for control functions, such as sleep function, high/low torque level or Ref loss.
100-0171-01
(120V Card)
2 A None 24VDC 1120 VAC input control circuitry

To purchase any Saftronics drives or information, contact us at:
Phone (815) 725-9696,
Toll Free (866) 492-9888,
Fax (815) 725-9393 or
E-mail info@joliettech.com